 First Edition
Jan 14 , 2002
Final Revision
******
O PTREX
LCD Module Technical Specification
T-51512D121J-FW-A-AA
Checked by (Quality Assurance Div.)
Checked by (Design Engineering Div.)
Table of Contents
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.
Prepared by (Production Div.)
Overview .................................................................................................................................................. 2 Absolute Maximum Ratings ........................................................................................................ 3 Electrical Characteristics .............................................................................................................. 3 Interface Pin Connection............................................................................................................... 6 Interface Timing ................................................................................................................................. 7 Block Diagram .................................................................................................................................... 10 Mechanical Specification...............................................................................................................11 Optical Characteristics ................................................................................................................ 14 Reliability Test Condition.......................................................................................................... 16 Inspection Standards ...................................................................................................................... 17 Handling Precautions for TFT-LCD Module ................................................................. 18
Revision History
Rev. Date Page Comment
w
w
w
.D
a
S ta
he
4U et
.c
om
w
w w
.D
at
aS
he
4U et
.c
om
T-51512-D121J-FW-A-AA
o .c m
OPTREX CORPORATION
Page 1/19
w
w
w
.D
aS at
he
et
4U
1. OVERVIEW
T-51512-D121J-FW-A-AA is 12.1" color TFT-LCD (Thin Film Transistor Liquid Crystal Display) module composed of LCD panel, driver ICs, control circuit, and backlight unit. By applying 6 bit digital data, 800 600, 260 K-color images are displayed on the 12.1" diagonal screen. Input power voltage is single 3.3V or 5.0V for LCD driving. Both 3.3 V-CMOS and 5.0 VCMOS level voltage are acceptable for logic input voltage. Inverter for backlight is not included in this module. General specifications are summarized in the following table:
ITEM Display Area (mm) Number of Dots Pixel Pitch (mm) Color Pixel Arrangement Display Mode Number of Color Optimum Viewing Angle(Contrast ratio) Brightness (cd/m2) Module Size (mm) Module Mass (g) Backlight Unit Surface Treatment
SPECIFICATION 246.0 184.5 (12.106-inch diagonal) 800 3 (H) 600 (V) 0.3075 (H) 0.3075 (V) RGB vertical stripe normally white 260 K 6 o'clock 300 280.0 (W) 210.0 (H) 12.0 (D) 740 CCFL, 2-tubes, edge-light, replaceable Antiglare and hard-coating 3H
Characteristic value without any note is typical value. The LCD product described in this specification is designed and manufactured for the standard use in OA equipment and consumer products, such as computers, communication equipment, industrial robots, AV equipment and so on. Do not use the LCD product for the equipment that require the extreme high level of reliability, such as aerospace applications, submarine cables, nuclear power control systems and medical or other equipment for life support. ADI assumes no responsibility for any damage resulting from the use of the LCD product in disregard of the conditions and handling precautions in this specification. If customers intend to use the LCD product for the above items or other no standard items, please contact our sales persons in advance.
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 2/19
2. ABSOLUTE MAXIMUM RATINGS
ITEM Power Supply Voltage for LCD Logic Input Voltage Lamp Voltage Lamp Current Lamp Frequency Operation Temperature *) Storage Temperature *) SYMBOL VCC VI VL IL FL Top Tstg MIN. 0 0 0 0 --0 -20 MAX 6.0 6.5 3000 15 60 50 60 UNIT V V Vrms mArms kHz C C
*) Top,Tstg 40C : 90%RH max. without condensation Top,Tstg > 40C : Absolute humidity shall be less than the value of 90%RH at 40C without condensation.
3. ELECTRICAL CHARACTERISTICS
(1) TFT-LCD Ambient temperature: Ta = 25*Z ITEM Power Supply Voltage for LCD Power Supply 3.3V powered 5.0V powered 3.3V powered SYMBOL VCC VCC ICC ICC VRP VIH VIL MIN. 3.0 4.75 2.0 0 TYP. 3.3 5.0 335 235 MAX. 3.6 5.25 430 340 100 5.25 0.8 UNIT V V mA mA Remarks
A), D) A), D)
VCC = 3.3 V B) VCC = 5.0 V B)
Current for LCD 5.0V powered Permissive Input Ripple Voltage Logic Input Voltage (2) Backlight High Low
mVp-p VCC = +3.3V/5.0V V V
Ta = 25*Z ITEM Lamp Voltage Lamp Current Lamp Frequency Starting Lamp Voltatge
SYMBOL
MIN. 6.0 30 1000 1200 50,000
TYP. 600 10.0 C)
MAX. 12.0 60 -
UNIT Vrms mArms kHz Vrms
Remarks IL = 10.0 mArms
Note 1) Note 2)
VL IL FL VS
Ta = 25C Ta = 0C
Note 3) Note 3)
Lamp Life Time
LT
h
IL = 10.0 mArms, Continuous operation
Note 3),4)
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 3/19
[Note] 1) Lamp Current measurement method (The current meter is inserted in low voltage line.)
CTL LCD Module CTH CTH A Power Inverter Supply
2) Lamp frequency of inverter may produce interference with horizontal synchronous frequency, and this may cause horizontal beat on the display. Therefore, please adjust lamp frequency, and keep inverter as far from module as possible or use electronic shielding between inverter and module to avoid the interference. 3) Lamp life time is defined as the time either when the brightness becomes 50% of the initial value, or when the starting lamp voltage does not meet the value specified in this table. 4) The life time of the backlight depends on the ambient temperature. The life time will decrease under low/high temperature. A) Power and signals sequence: t0 1 ms t1 15 ms 0 < t2 200 ms 0 < t3 1 s (a) 3.3 V powered
3.0V 2.1V Data, Timing signals 1.7V 0.5V 1.7V VCC 3.0V
0 < t4 50 ms 400 ms t5 200 ms t6 0 t7
t0
t1
t2 Backlight
t3
t4
t5
t7 t6 data: RGB DATA, DCLK, HD, VD, DENA ,
(b) 5.0 V powered
4.5V 2.1V Data, Timing signals 1.7V 0.5V 1.7V VCC 4.5V
t0
t1
t2 Backlight
t3
t4
t5
t7 t6 data: RGB DATA, DCLK, HD, VD, DENA ,
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 4/19
VCC-dip conditions: (a) 3.3 V powered 1) When 2.7 V VCC < 3.0 V, td 10 ms 2) When VCC < 2.7 V VCC-dip conditions should also follow the power and signals sequence.
VCC
3.0V
td
(b) 5.0V powered 1) When 4.2 V VCC < 4.5 V, td 10 ms 2) When VCC < 4.2 V VCC-dip conditions should also follow the power and signals sequence.
VCC
2.7V
4.5V
V V
td
B) Typical current condition: 64-gray-bar pattern 600 line mode VCC = +3.3 V / 5.0 V, fH=37.9kHz, fV=60.3Hz, fCLK= 40MHz C) For typical luminance of 300cd/m2 D) Please do not supply 3.6 ~ 4.75 V constantly as Power Supply Voltage for LCD. The condition is shown as t1 15 ms.
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
4.2V
Page 5/19
4. INTERFACE PIN CONNECTION
CN 1(INTERFACE SIGNAL) Used connector: DF9B-41P-1V(Hirose) Corresponding connector: DF9B-41S-1V(Hirose) Pin No. Symbol Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 GND DCLK GND HD VD GND GND GND R0 R1 R2 GND R3 R4 R5 GND GND GND G0 G1 G2 GND G3 G4 G5 GND GND GND B0 B1 B2 GND B3 B4 B5 GND DENA NC VCC VCC TEST Signal ground Clock signal for sampling catch data signal Signal ground Horizontal sync signal Vertical sync signal Signal ground Signal ground Signal ground RED data signal(LSB) RED data signal RED data signal Signal ground RED data signal RED data signal RED data signal(MSB) Signal ground Signal ground Signal ground GREEN data signal(LSB) GREEN data signal GREEN data signal Signal ground GREEN data signal GREEN data signal GREEN data signal(MSB) Signal ground Signal ground Signal ground BLUE data signal (LSB) Blue data signal BLUE data signal Signal ground BLUE data signal BLUE data signal BLUE data signal(MSB) Signal ground Data enable signal(to settle the viewing area) +3.3 / 5.0 V Power supply +3.3 / 5.0 V Power suppply This pin should be open. Test signal output for only internal test use.
*)The shielding case is connected with GND.
T-51512-D121J-FW-A-AA OPTREX CORPORATION Page 6/19
CN 2(BACKLIGHT) Backlight-side connector: BHR-04VS-1 (JST) Inverter-side connector: SM04(4.0)B-BHS-1(JST) Pin No. 1, 2 4 VBLH - VBLL = VL Symbol CTH CTL Function VBLH (High voltage) VBLL (Low voltage)
5. INTERFACE TIMING
(1) Timing Specifications VCC = 3.3/5.0 V, Ta = 25*Z ITEM Frequency DCLK *
1,4)
SYMBOL fCLK TCLK tWCL tWCH tDS tDH tHA tHFP tHBP tVA tVFP tVBP fH tH tWHL fV tV tWVL
MIN 35 25 10 10 4 4 800 0 10 600 1 2 35.2 25.5 5 55 15.6 1
TYP ------800 --600 --37.9 26.4 -60.3 16.6 --
MAX 40 27.8 ----800 --
UNIT MHz Ns Ns Ns Ns Ns tCLK tCLK tCLK
Period Low Width High Width
DATA *
1)
Set up time Hold time Horizontal Active Time Horizontal Front Porch
(R,G,B,DENA, HD, VD)
DENA*3)
Horizontal Back Porch Vertical Active Time Vertical Front Porch Vertical Back Porch Frequency
600 --
tH tH tH
39.2 28.4 -64.2 18.2 --
kHz ms tCLK Hz ms tH
HD*2,4)
Period Low Width Frequency
VD*2)
Period Low Width
[Note] *1) DATA is latched at fall edge of DCLK in this specification. *2) Polarities of HD and VD are negative in this specification. *3) DENA (Data Enable) should always be positive polarity as shown in the timing specification. *4) DCLK should appear during all invalid period, and HD should appear during invalid period of frame cycle.
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 7/19
(2) Timing Chart a. Pixel Timing Chart
tWCH tCLK tWCL 2.0V 0.8V
DCLK
tDr
tDg 2.0V 0.8V
DATA (R,G,B), DENA, HD, VD
b. Horizontal Timing Chart
DCLK
First Data
DATA (R,G,B)
Invalid Data
1
2
3
799
800
Invalid Data Last Data
tHFP
tHBP
tHA
DENA
tH=1/fH tWHL
HD
c. Vertical Timing Chart
HD
LINE DATA
Invalid Data
1
2
3
599
600
Invalid Data
tVFP
tVBP
tVA
DENA
tV=1/fV tWVL
VD
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 8/19
(3) Color Data Assignment
R DATA
COLOR
G DATA R1 R0 G5 G4 G3 G2 G1 G0 B5 B4
B DATA B3 B2 B1 B0
LSB
INPUT DATA
R5
MSB
R4
R3
R2
LSB MSB
LSB MSB
BLACK RED(63) GREEN(63) BASIC BLUE(63) COLOR CYAN MAGENTA YELLOW WHITE RED(0) RED (1) RED(2) RED
0 1 0 0 0 1 1 1 0 0 0
0 1 0 0 0 1 1 1 0 0 0
0 1 0 0 0 1 1 1 0 0 0
0 1 0 0 0 1 1 1 0 0 0
0 1 0 0 0 1 1 1 0 0 1
0 1 0 0 0 1 1 1 0 1 0
0 0 1 0 1 0 1 1 0 0 0
0 0 1 0 1 0 1 1 0 0 0
0 0 1 0 1 0 1 1 0 0 0
0 0 1 0 1 0 1 1 0 0 0
0 0 1 0 1 0 1 1 0 0 0
0 0 1 0 1 0 1 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
0 0 0 1 1 1 0 1 0 0 0
RED (62) RED(63) GREEN(0) GREEN (1) GREEN(2) GREEN
1 1 0 0 0
1 1 0 0 0
1 1 0 0 0
1 1 0 0 0
1 1 0 0 0
0 1 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 1
0 0 0 1 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
GREN(62) GREEN(63) BLUE(0) BLUE(1) BLUE(2) BLUE
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
1 1 0 0 0
1 1 0 0 0
1 1 0 0 0
1 1 0 0 0
1 1 0 0 0
0 1 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
0 0 0 0 1
0 0 0 1 0
BLUE(62) BLUE(63)
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
1 1
1 1
1 1
1 1
1 1
0 1
[Note] 1) Definition of gray scale Color (n) ---n indicates gray scale level. Higher n means brighter level. 2) Data 1:High, 0: Low
T-51512-D121J-FW-A-AA OPTREX CORPORATION Page 9/19
6. BLOCK DIAGLAM
Timing signal Display data
Timing Converter
G1 Drivers(gate) G2 TFT-LCD
Power
I/F Connector
G600 S2399 S2400
Page 10/19
S1
Power Supply Circuit
Drivers(source)
BACKLIGHT CN2 1 2 4
CCFL
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
S2
7. MECHANICAL SPECIFICATIONS
(1) Front Side
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 11/19
(2) Rear Side
[Note] We recommend you referring to the detailed drawing for your design. Please contact our company sales representative when you need the detailed drawing.
T-51512-D121J-FW-A-AA OPTREX CORPORATION Page 12/19
8. OPTICAL CHARACTERISTICS
Ta=25C, VCC=3.3V / 5.0V, Input Signals: Typ. Values shown in Section 5
ITEM Contrast Ratio Luminance Response Time Viewing Angle Horizontal Vertical Red Color Coordinates Blue White Green
SYMBOL CONDITION CR Lw tr tf f q tis Rx Ry Gx Gy Bx By Wx Wy q = f = 0 2h q = f = 0 q = f = 0 q = f = 0 q = f = 0 CR 10
MIN 100 250 ---50~50 -40~30 -0.535 0.318 0.296 0.517 0.139 0.159 0.299 0.345
TYP 300 300 20 30 -60~60 -50~40 -0.565 0.348 0.326 0.547 0.169 0.189 0.329 0.375
MAX --40 50 --2 0.595 0.378 0.356 0.577 0.199 0.219 0.359 0.405
UNIT Remarks -cd/m ms ms s
2
*1)*3) *2)*3) *3)*4) *3)*4) *3) *3) *5)
Image sticking
--
*3)
[Note] These items are measured using BM-5A(TOPCON) or LCD-7000(Otsuka Electronic) under the dark room condition (no ambient light). Condition: IL = 10.0 mArms, FL=47kHz *1) Definition of Contrast Ratio CR=ON (White) Luminance / OFF(Black) Luminance: average of 5 points *2) Definition of Luminance Lw= ON (White) Luminance: average of 5 points
200 (1, 1) 1 5 3 4 400 600 *v
150 300 450
2
(800, 600)
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 13/19
*3) Definition of Viewing Angle( q , f)
*4) Definition of Response Time
White 90% 90%
Luminance
10% tr
Black
10%
tf
5) Image sticking: Continuously display the test pattern shown in the figure below for two-hours. Then display a completely white screen. The previous image shall not persist more than two seconds at 25C. TEST PATTERN FOR IMAGE STICKING TEST
Cols 388-402
White Area Rows 298-302 Black Lines
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 14/19
9. RELIABILITY TEST CONDITION
(1) Temperature and Humidity TEST ITEM HIGH TEMPERATURE HIGH HUMIDITY OPERATION HIGH TEMPERATURE STORAGE LOW TEMPERATURE STORAGE THERMAL SHOCK CONDITIONS 40C, 90%RH, 240 h 60C, 96 h -20C, 96 h BETWEEN -20C (1h) and 60C(1h), 5 CYCLES
(2) Shock & Vibration ITEM CONDITIONS Shock level: 1470m/s2 (150G) SHOCK Waveform: half sinusoidal wave, 2ms (NON-OPERATION) Number of shocks: one shock input in each direction of three mutually perpendicular axes for a total of six shock inputs Vibration level: 9.8m/s2 (1.0G) Waveform: sinusoidal VIBRATION Frequency range: 5 to 500Hz
(NON-OPERATION) Frequency sweep rate: 0.5 octave /min Duration: one sweep from 5 to 500 Hz in each of three mutually perpendicular axis(each x,y,z axis: 1 hour, total 3 hours) (3) Judgment standard The judgment of the above tests should be made as follow: Pass: Normal display image with no obvious non-uniformity and no line defect. Partial transformation of the module parts should be ignored. Fail: No display image, obvious non-uniformity, or line defects.
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 15/19
10. INSPECTION STANDARDS
Inspection condition is as follows: Viewing distance is approximately 35 cm. Viewing angle is normal to the LCD panel. Ambient temperature is approximately 25C. Ambient light is from 300 to 500 lx. Bright Dot is defined as follows: Visible through 5% transmission ND filter under the condition that black image (color 0) is on the display. DEFECT TYPE POLARIZER SCRATCH DENT, BUBBLE BRIGHT DOT DARK DOT TOTAL DOT TWO ADJACENT DOT BRIGHT DOT DARK DOT THREE OR MORE ADJACENT DOT DISTANCE BETWEEN DEFECTS BRIGHT DOT DARK DOT LINE DEFECT LIMIT 0.01mm < W 0.05mm, L 2.0mm, N 2 D 0.3mm, N 2 N5 N5 N8 2 PAIRS 2 PAIRS
DOT DEFECT
NOT ALLOWED
15mm 15mm NOT ALLOWED
*1) W: width,*@ length,*@ diameter,*@ number L: D: N: *2) DEFINITION OF ADJACENT
RGBRGBRGB
Defective Dot
RGBRGBRGB
Adjacent Dots
RGBRGBRGB
The defects that are not defined above and considered to be problem shall be reviewed and discussed by both parties.
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 16/19
11. HANDLING PRECAUTIONS FOR TFT-LCD MODULE
Please pay attention to the followings in handling TFT-LCD products;
(1) ASSEMBLY PRECAUTION
a. Please use the mounting hole on the module in installing and do not bending or wrenching LCD in assembling. And please do not drop, bend or twist LCD module in handling. b. Please design display housing in accordance with the following guide lines. (a) Housing case must be designed carefully so as not to put stresses on LCD all sides and not to wrench module. The stresses may cause non-uniformity even if there is no nonuniformity statically. (b) Keep sufficient clearance between LCD module back surface and housing when the LCD module is mounted. Approximately 1.0mm of the clearance in the design is recommended taking into account the tolerance of LCD module thickness and mounting structure height on the housing. (c) When some parts, such as, FPC cable and ferrite plate, are installed underneath the LCD module, still sufficient clearance is required, such as 0.5mm. This clearance is, especially, to be reconsidered when the additional parts are implemented for EMI countermeasure. (d) Design the inverter location and connector position carefully so as not to give stress to lamp cable, or not to interface the LCD module by the lamp cable. (e) Keep sufficient clearance between LCD module and the others parts, such as inverter and speaker so as not to interface the LCD module. Approximately 1.0mm of the clearance in the design is recommended. c. Please do not push or scratch LCD panel surface with anything hard. And do not soil LCD panel surface by touching with bare hands. (Polarizer film, surface of LCD panel is easy to be flawed.) d. Please do not press any parts on the rear side such as source TCP, gate TCP, control circuit board and FPCs during handling LCD module. If pressing rear part is unavoidable, handle the LCD module with care not to damage them. e. Please wipe off LCD panel surface with absorbent cotton or soft cloth in case of it being soiled. f. Please wipe off drops of adhesives like saliva and water on LCD panel surface immediately. They might damage to cause panel surface variation and color change. g. Please do not take a LCD module to pieces and reconstruct it. Resolving and reconstructing modules may cause them not to work well. h. Please do not touch metal frames with bare hands and soiled gloves. A color change of the metal frames can happen during a long preservation of soiled LCD modules.
T-51512-D121J-FW-A-AA OPTREX CORPORATION Page 17/19
i. Please handle metal frame carefully to avoid getting hurt because edge of metal frame is very sharp. j. Please pay attention to handling lead wire of backlight so that it is not tugged in connecting with inverter. k. Be sure to connect the cables and the connecters correctly. l. Please connect the metal frame of LCD module to GND in order to minimize the effect of external noise and EMI.
(2) OPERATING PRECAUTIONS
a. Please be sure to turn off the power supply before connecting and disconnecting signal input cable. b. Please do not change variable resistance settings in LCD module. They are adjusted to the most suitable value. If they are changed, it might happen LCD does not satisfy the characteristics specification. c. LCD backlight takes longer time to become stable of radiation characteristics in low temperature than in room temperature. d. A condensation might happen on the surface and inside of LCD module in case of sudden change of ambient temperature. e. Please pay attention not to display the same pattern for very long time. Image might stick on LCD. Even if image sticking happens, it may disappear as the operation time proceeds. f. Please obey the same safe instructions as ones being prepared for ordinary electronic products.
(3) PRECAUTIONS WITH ELECTROSTATICS
a. This LCD module use CMOS-IC on circuit board and TFT-LCD panel, and so it is easy to be affected by electrostatics. Please be careful with electrostatics by the way of your body connecting to the ground and so on. b. Please remove protection film very slowly from the surface of LCD module to prevent from electrostatics occurrence.
(4) STORAGE PRECAUTIONS
a. Please do not leave the LCDs in the environment of high humidity and high temperature such as 60C90%RH. b. Please do not leave the LCDs in the environment of low temperature; below -20C.
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 18/19
(5) SAFETY PRECAUTIONS
a. When you waste damaged or unnecessary LCDs, it is recommended to crush LCDs into pieces and wash them off with solvents such as acetone and ethanol, which should later be burned. b. If any liquid leaks out of a damaged glass cell and comes in contact with the hands, wash off thoroughly with soap and water. c. Be sure to turn off the power supply when inserting or disconnecting the cable. d. Inverter should be designed carefully so as not to keep working in case of detecting over current or open circuit on the lamp.
(6) OTHERS
a. A strong incident light into LCD panel might cause display characteristics changing inferior because of polarizer film, color filter, and other materials becoming inferior. Please do not expose LCD module direct sunlight and strong UV rays. b. Please pay attention to a panel side of LCD module not to contact with other materials in preserving it alone. c. For the packaging box, please pay attention to the followings; (a) Packaging box and inner case for LCD are designed to protect the LCDs from the damage or scratching during transportation. Please do not open except picking LCDs up from the box. (b) Please do not pile them up more than 5 boxes. (They are not designed so.) And please do not turn over. (c) Please handle packaging box with care not to give them sudden shock and vibrations. And also please do not throw them up. (d) Packaging box and inner case for LCDs are made of cardboard. So please pay attention not to get them wet. (Such like keeping them in high humidity or wet place can occur getting them wet.)
T-51512-D121J-FW-A-AA
OPTREX CORPORATION
Page 19/19


▲Up To Search▲   

 
Price & Availability of T-51512D121F-FWAAA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X